This adds a bunch of messages to retrieve and set various things on the controller. It also groups the messages under one export to simplify the process of using and discovering many of them from one location. Some of these are WIP/probably not portable to other systems. This also adds the ability to set multiple circuits at once.
71 lines
2.3 KiB
TypeScript
71 lines
2.3 KiB
TypeScript
"use strict";
|
|
|
|
import { FindUnits } from "./finder.js";
|
|
import { messages } from "./messages/messages.js";
|
|
import { Unit } from "./unit.js";
|
|
|
|
console.log("searching...");
|
|
const f = new FindUnits();
|
|
const units = await f.searchAsync(1000);
|
|
f.close();
|
|
console.log("Discovered units:", units);
|
|
|
|
if (units.length === 0) {
|
|
throw new Error("no IntelliCenter units found, exiting.");
|
|
}
|
|
|
|
if (units.length > 1) {
|
|
throw new Error(
|
|
`found more than one IntelliCenter unit, unsure which one to use. ${JSON.stringify(units)}`,
|
|
);
|
|
}
|
|
|
|
const endpoint = units[0].addressStr;
|
|
const port = units[0].port;
|
|
|
|
// const endpoint = "10.0.0.41";
|
|
// const port = 6680;
|
|
|
|
console.log("connecting to intellicenter device at", endpoint, "port", port);
|
|
const unit = new Unit(endpoint, port);
|
|
await unit.connect();
|
|
console.log("connected");
|
|
|
|
console.log("sending Get System Info request...");
|
|
let resp = await unit.send(messages.GetSystemInformation());
|
|
console.log("got response:", JSON.stringify(resp, null, 2));
|
|
|
|
console.log("sending Get System Config request...");
|
|
resp = await unit.send(messages.GetSystemConfiguration());
|
|
console.log("got response:", JSON.stringify(resp, null, 2));
|
|
|
|
console.log("sending Get Body Status request...");
|
|
resp = await unit.send(messages.GetBodyStatus());
|
|
console.log("got response:", JSON.stringify(resp, null, 2));
|
|
|
|
console.log("sending Get Chemical Status request...");
|
|
resp = await unit.send(messages.GetChemicalStatus());
|
|
console.log("got response:", JSON.stringify(resp, null, 2));
|
|
|
|
console.log("sending Get Heaters request...");
|
|
resp = await unit.send(messages.GetHeaters());
|
|
console.log("got response:", JSON.stringify(resp, null, 2));
|
|
|
|
// console.log("sending Set Setpoint request...");
|
|
// resp = await unit.send(messages.SetSetpoint("B1202", 97));
|
|
// console.log("got response:", JSON.stringify(resp, null, 2));
|
|
|
|
// console.log("turning off pool...");
|
|
// resp = await unit.send(messages.SetItemStatus("B1101", false));
|
|
// console.log("got response:", JSON.stringify(resp, null, 2));
|
|
|
|
// console.log("turning off water feature...");
|
|
// resp = await unit.send(messages.SetItemStatus("C0003", false));
|
|
// console.log("got response:", JSON.stringify(resp, null, 2));
|
|
|
|
console.log("sending Set Heatmode request...");
|
|
resp = await unit.send(messages.SetHeatMode("B1202", true));
|
|
console.log("got response:", JSON.stringify(resp, null, 2));
|
|
|
|
unit.close();
|