Get control labels, status working
This gets everything working in the module except the ability to turn circuits on and off and set heat temperatures.
This commit is contained in:
@ -26,6 +26,7 @@ const poolData = {
|
||||
saltPPM: 0,
|
||||
saturation: 0,
|
||||
freezeMode: false,
|
||||
circuits: {},
|
||||
};
|
||||
let poolObjnam = "B1101";
|
||||
let spaObjnam = "B1202";
|
||||
@ -222,6 +223,14 @@ module.exports = NodeHelper.create({
|
||||
if (obj.params.STATUS) {
|
||||
poolData.freezeMode = obj.params.STATUS === "ON";
|
||||
}
|
||||
} else if (Object.keys(poolData.circuits).includes(obj.objnam)) {
|
||||
Log.info(
|
||||
`[MMM-IntelliCenter] received update for circuit ${obj.objnam}`,
|
||||
);
|
||||
|
||||
if (obj.params.STATUS) {
|
||||
poolData.circuits[obj.objnam].status = obj.params.STATUS === "ON";
|
||||
}
|
||||
} else {
|
||||
Log.info(
|
||||
`[MMM-IntelliCenter] received update for untracked object: ${obj.objnam}`,
|
||||
@ -267,11 +276,37 @@ module.exports = NodeHelper.create({
|
||||
|
||||
Log.info("[MMM-IntelliCenter] getting circuit information...");
|
||||
const circuits = await foundUnit.send(messages.GetCircuitStatus());
|
||||
const freezeCirc = circuits.objectList?.find((obj) => obj.params?.SUBTYP === "FRZ");
|
||||
const freezeCirc = circuits.objectList?.find(
|
||||
(obj) => obj.params?.SUBTYP === "FRZ",
|
||||
);
|
||||
if (freezeCirc) {
|
||||
freezeObjnam = freezeCirc.objnam;
|
||||
Log.info(`[MMM-IntelliCenter] registering for freeze-protection updates...`);
|
||||
await foundUnit.send(messages.SubscribeToUpdates(freezeObjnam, "STATUS"));
|
||||
Log.info(
|
||||
`[MMM-IntelliCenter] registering for freeze-protection updates...`,
|
||||
);
|
||||
await foundUnit.send(
|
||||
messages.SubscribeToUpdates(freezeObjnam, "STATUS"),
|
||||
);
|
||||
}
|
||||
if (this.config.controls?.length > 0) {
|
||||
for (const circuit of circuits.objectList) {
|
||||
const wantedControl = this.config.controls.find(
|
||||
(c) => c.id === circuit.objnam,
|
||||
);
|
||||
if (!wantedControl) {
|
||||
continue;
|
||||
}
|
||||
|
||||
poolData.circuits[circuit.objnam] = {
|
||||
status: false,
|
||||
name: circuit.params.SNAME,
|
||||
};
|
||||
}
|
||||
}
|
||||
|
||||
for (const circuit of Object.keys(poolData.circuits)) {
|
||||
Log.info(`[MMM-IntelliCenter] registering for ${circuit} updates...`);
|
||||
await foundUnit.send(messages.SubscribeToUpdates(circuit, "STATUS"));
|
||||
}
|
||||
|
||||
if (bodyUpdates.length > 0) {
|
||||
|