Circuits, heat modes, and heat setpoints all function as expected now. Also refactored a little bit for better code practices and created DOM controls through more appropriate means than just a bunch of strings, which allowed access to member functions rather than loose functions that were problematic for linting, accessing the appropriate unit, etc.
453 lines
14 KiB
JavaScript
453 lines
14 KiB
JavaScript
/* global module require clearInterval clearTimeout setTimeout setInterval config */
|
|
|
|
var NodeHelper = require("node_helper");
|
|
|
|
const { FindUnits, Unit } = require("node-intellicenter");
|
|
const messages = require("node-intellicenter/messages");
|
|
const Log = require("logger");
|
|
|
|
const reconnectDelayMs = 10 * 1000;
|
|
const unitFinderTimeoutMs = 5 * 1000;
|
|
let foundUnit;
|
|
const poolData = {
|
|
poolTemp: 0,
|
|
spaTemp: 0,
|
|
poolSetPoint: 0,
|
|
spaSetPoint: 0,
|
|
poolHeaterStatus: false,
|
|
spaHeaterStatus: false,
|
|
poolStatus: false,
|
|
spaStatus: false,
|
|
phVal: 0,
|
|
lastPHVal: 0,
|
|
phTank: 0,
|
|
orp: 0,
|
|
lastOrpVal: 0,
|
|
saltPPM: 0,
|
|
saturation: 0,
|
|
freezeMode: false,
|
|
circuits: {},
|
|
};
|
|
let poolObjnam = "B1101";
|
|
let spaObjnam = "B1202";
|
|
let refreshTimer;
|
|
let unitFinderRetry;
|
|
let unitReconnectTimer;
|
|
let intellichemObjnam = "";
|
|
let chlorinatorObjnam = "";
|
|
let freezeObjnam = "";
|
|
let initialConnectDone = false;
|
|
|
|
module.exports = NodeHelper.create({
|
|
setCircuit(circuitState) {
|
|
if (!foundUnit) {
|
|
return;
|
|
}
|
|
|
|
Log.info(
|
|
`[MMM-IntelliCenter] setting circuit ${circuitState.id} to ${!!circuitState.state}`,
|
|
);
|
|
foundUnit.send(
|
|
messages.SetObjectStatus(circuitState.id, !!circuitState.state),
|
|
);
|
|
},
|
|
|
|
setHeatpoint(heatpoint) {
|
|
if (!foundUnit) {
|
|
return;
|
|
}
|
|
|
|
let heatObjnam = "";
|
|
if (heatpoint.body === "spa") {
|
|
heatObjnam = spaObjnam;
|
|
} else if (heatpoint.body === "pool") {
|
|
heatObjnam = poolObjnam;
|
|
}
|
|
|
|
if (!heatObjnam) {
|
|
Log.error(
|
|
`[MMM-IntelliCenter] unable to determine objnam from given heatpoint body ${heatpoint.body} - expected "spa" or "pool"`,
|
|
);
|
|
return;
|
|
}
|
|
|
|
Log.info(
|
|
`[MMM-IntelliCenter] setting heatpoint for body ${heatObjnam} to ${heatpoint.temperature} deg`,
|
|
);
|
|
foundUnit.send(messages.SetSetpoint(heatObjnam, heatpoint.temperature));
|
|
},
|
|
|
|
setHeatstate(heatstate) {
|
|
if (!foundUnit) {
|
|
return;
|
|
}
|
|
let heatObjnam = "";
|
|
if (heatstate.body === "spa") {
|
|
heatObjnam = spaObjnam;
|
|
} else if (heatstate.body === "pool") {
|
|
heatObjnam = poolObjnam;
|
|
}
|
|
|
|
if (!heatObjnam) {
|
|
Log.error(
|
|
`[MMM-IntelliCenter] unable to determine objnam from given heatstate body ${heatstate.body} - expected "spa" or "pool"`,
|
|
);
|
|
return;
|
|
}
|
|
|
|
Log.info(
|
|
`[MMM-IntelliCenter] setting heat state for body ${heatObjnam} to ${!!heatstate.state}`,
|
|
);
|
|
foundUnit.send(messages.SetHeatMode(heatObjnam, !!heatstate.state));
|
|
},
|
|
|
|
setLightcmd(lightCmd) {
|
|
if (!foundUnit) {
|
|
return;
|
|
}
|
|
|
|
Log.info(`[MMM-IntelliCenter] sending light command ${lightCmd}`);
|
|
// NYI in node-intellicenter
|
|
// foundUnit.send(messages.SendLightCommand(lightCmd));
|
|
},
|
|
|
|
notifyReconnecting() {
|
|
this.sendSocketNotification("INTELLICENTER_RECONNECTING");
|
|
},
|
|
|
|
socketNotificationReceived(notification, payload) {
|
|
if (notification === "INTELLICENTER_CONFIG") {
|
|
if (!this.config) {
|
|
this.config = payload;
|
|
this.connect(
|
|
(status) => {
|
|
this.sendSocketNotification("INTELLICENTER_RESULT", status);
|
|
},
|
|
() => {
|
|
this.notifyReconnecting();
|
|
},
|
|
);
|
|
} else if (poolData) {
|
|
this.sendSocketNotification("INTELLICENTER_RESULT", poolData);
|
|
}
|
|
// If we don't have a status yet, assume the initial connection is still in progress and this socket notification will be delivered when setup is done
|
|
}
|
|
if (notification === "INTELLICENTER_CIRCUIT") {
|
|
this.setCircuit(payload);
|
|
}
|
|
if (notification === "INTELLICENTER_HEATPOINT") {
|
|
this.setHeatpoint(payload);
|
|
}
|
|
if (notification === "INTELLICENTER_HEATSTATE") {
|
|
this.setHeatstate(payload);
|
|
}
|
|
if (notification === "INTELLICENTER_LIGHTCMD") {
|
|
this.setLightcmd(payload);
|
|
}
|
|
},
|
|
|
|
resetFoundUnit() {
|
|
foundUnit = null;
|
|
if (refreshTimer) {
|
|
clearInterval(refreshTimer);
|
|
refreshTimer = null;
|
|
}
|
|
if (unitFinderRetry) {
|
|
clearInterval(unitFinderRetry);
|
|
unitFinderRetry = null;
|
|
}
|
|
if (unitReconnectTimer) {
|
|
clearTimeout(unitReconnectTimer);
|
|
unitReconnectTimer = null;
|
|
}
|
|
},
|
|
|
|
setupUnit(cb, reconnectCb) {
|
|
Log.info("[MMM-IntelliCenter] initial connection to unit...");
|
|
initialConnectDone = false;
|
|
|
|
foundUnit
|
|
.on("error", (e) => {
|
|
Log.error(
|
|
`[MMM-IntelliCenter] error in unit connection. restarting the connection process in ${reconnectDelayMs / 1000} seconds`,
|
|
);
|
|
Log.error(e);
|
|
|
|
reconnectCb();
|
|
this.resetFoundUnit();
|
|
unitReconnectTimer = setTimeout(() => {
|
|
this.connect(cb, reconnectCb);
|
|
}, reconnectDelayMs);
|
|
})
|
|
.on("close", () => {
|
|
Log.error(
|
|
`[MMM-IntelliCenter] unit connection closed unexpectedly. restarting the connection process in ${reconnectDelayMs / 1000} seconds`,
|
|
);
|
|
|
|
reconnectCb();
|
|
this.resetFoundUnit();
|
|
unitReconnectTimer = setTimeout(() => {
|
|
this.connect(cb, reconnectCb);
|
|
}, reconnectDelayMs);
|
|
})
|
|
.on("notify", (msg) => {
|
|
// todo: how to find freezeMode on/off?
|
|
for (const obj of msg.objectList) {
|
|
if (obj.objnam === intellichemObjnam) {
|
|
Log.info("[MMM-IntelliCenter] received chemical update");
|
|
|
|
if (obj.params.ORPVAL) {
|
|
poolData.orp = parseInt(obj.params.ORPVAL);
|
|
}
|
|
if (obj.params.PHVAL) {
|
|
poolData.phVal = parseFloat(obj.params.PHVAL);
|
|
}
|
|
if (obj.params.PHTNK) {
|
|
poolData.phTank = parseInt(obj.params.PHTNK);
|
|
}
|
|
if (obj.params.QUALTY) {
|
|
poolData.saturation = parseFloat(obj.params.QUALTY);
|
|
}
|
|
|
|
if (poolData.phVal !== 0) {
|
|
poolData.lastPHVal = poolData.phVal;
|
|
}
|
|
if (poolData.orp !== 0) {
|
|
poolData.lastOrpVal = poolData.orp;
|
|
}
|
|
} else if (obj.objnam === poolObjnam) {
|
|
Log.info("[MMM-IntelliCenter] received pool update");
|
|
|
|
if (obj.params.LOTMP) {
|
|
poolData.poolSetPoint = parseInt(obj.params.LOTMP);
|
|
}
|
|
// todo: is MODE the right check for this?
|
|
if (obj.params.MODE) {
|
|
poolData.poolHeaterStatus = obj.params.MODE === "11";
|
|
}
|
|
if (obj.params.STATUS) {
|
|
poolData.poolStatus = obj.params.STATUS === "ON";
|
|
}
|
|
if (obj.params.LSTTMP) {
|
|
poolData.poolTemp = parseInt(obj.params.LSTTMP);
|
|
}
|
|
} else if (obj.objnam === spaObjnam) {
|
|
Log.info("[MMM-IntelliCenter] received spa update");
|
|
|
|
if (obj.params.LOTMP) {
|
|
poolData.spaSetPoint = parseInt(obj.params.LOTMP);
|
|
}
|
|
// todo: is MODE the right check for this?
|
|
if (obj.params.MODE) {
|
|
poolData.spaHeaterStatus = obj.params.MODE === "11";
|
|
}
|
|
if (obj.params.STATUS) {
|
|
poolData.spaStatus = obj.params.STATUS === "ON";
|
|
}
|
|
if (obj.params.LSTTMP) {
|
|
poolData.spaTemp = parseInt(obj.params.LSTTMP);
|
|
}
|
|
} else if (obj.objnam === chlorinatorObjnam) {
|
|
Log.info("[MMM-IntelliCenter] received chlorinator update");
|
|
|
|
if (obj.params.SALT) {
|
|
poolData.saltPPM = parseInt(obj.params.SALT);
|
|
}
|
|
} else if (obj.objnam === freezeObjnam) {
|
|
Log.info("[MMM-IntelliCenter] received freeze-protection update");
|
|
|
|
if (obj.params.STATUS) {
|
|
poolData.freezeMode = obj.params.STATUS === "ON";
|
|
}
|
|
} else if (Object.keys(poolData.circuits).includes(obj.objnam)) {
|
|
Log.info(
|
|
`[MMM-IntelliCenter] received update for circuit ${obj.objnam}`,
|
|
);
|
|
|
|
if (obj.params.STATUS) {
|
|
poolData.circuits[obj.objnam].status = obj.params.STATUS === "ON";
|
|
}
|
|
} else {
|
|
Log.info(
|
|
`[MMM-IntelliCenter] received update for untracked object: ${obj.objnam}`,
|
|
);
|
|
}
|
|
}
|
|
|
|
if (initialConnectDone) {
|
|
cb(poolData);
|
|
}
|
|
})
|
|
.once("connected", async () => {
|
|
Log.info(
|
|
"[MMM-IntelliCenter] logged into unit. getting system configuration...",
|
|
);
|
|
const sysinfo = await foundUnit.send(messages.GetSystemConfiguration());
|
|
const bodyUpdates = [];
|
|
for (const obj of sysinfo.answer) {
|
|
if (obj.params.OBJTYP === "BODY" && obj.params.SUBTYP === "POOL") {
|
|
const ichem = obj.params.OBJLIST?.find(
|
|
(obj) => obj.params.SUBTYP === "ICHEM",
|
|
);
|
|
intellichemObjnam = ichem?.objnam;
|
|
|
|
poolObjnam = obj.objnam;
|
|
bodyUpdates.push(obj.objnam);
|
|
} else if (
|
|
obj.params.OBJTYP === "BODY" &&
|
|
obj.params.SUBTYP === "SPA"
|
|
) {
|
|
spaObjnam = obj.objnam;
|
|
bodyUpdates.push(obj.objnam);
|
|
}
|
|
}
|
|
|
|
Log.info("[MMM-IntelliCenter] getting chemical status...");
|
|
const chemstatus = await foundUnit.send(messages.GetChemicalStatus());
|
|
for (const obj of chemstatus.objectList) {
|
|
if (obj.params.SUBTYP === "ICHLOR") {
|
|
chlorinatorObjnam = obj.objnam;
|
|
}
|
|
}
|
|
|
|
Log.info("[MMM-IntelliCenter] getting circuit information...");
|
|
const circuits = await foundUnit.send(messages.GetCircuitStatus());
|
|
const freezeCirc = circuits.objectList?.find(
|
|
(obj) => obj.params?.SUBTYP === "FRZ",
|
|
);
|
|
if (freezeCirc) {
|
|
freezeObjnam = freezeCirc.objnam;
|
|
Log.info(
|
|
`[MMM-IntelliCenter] registering for freeze-protection updates...`,
|
|
);
|
|
await foundUnit.send(
|
|
messages.SubscribeToUpdates(freezeObjnam, "STATUS"),
|
|
);
|
|
}
|
|
if (this.config.controls?.length > 0) {
|
|
for (const circuit of circuits.objectList) {
|
|
const wantedControl = this.config.controls.find(
|
|
(c) => c.id === circuit.objnam,
|
|
);
|
|
if (!wantedControl) {
|
|
continue;
|
|
}
|
|
|
|
poolData.circuits[circuit.objnam] = {
|
|
status: false,
|
|
name: circuit.params.SNAME,
|
|
};
|
|
}
|
|
}
|
|
|
|
for (const circuit of Object.keys(poolData.circuits)) {
|
|
Log.info(`[MMM-IntelliCenter] registering for ${circuit} updates...`);
|
|
await foundUnit.send(messages.SubscribeToUpdates(circuit, "STATUS"));
|
|
}
|
|
|
|
if (bodyUpdates.length > 0) {
|
|
for (const obj of bodyUpdates) {
|
|
Log.info(
|
|
`[MMM-IntelliCenter] registering for ${obj === poolObjnam ? "pool" : obj === spaObjnam ? "spa" : obj} updates...`,
|
|
);
|
|
await foundUnit.send(
|
|
messages.SubscribeToUpdates(obj, [
|
|
"LOTMP",
|
|
"MODE",
|
|
"STATUS",
|
|
"LSTTMP",
|
|
]),
|
|
);
|
|
}
|
|
}
|
|
|
|
if (chlorinatorObjnam) {
|
|
Log.info(
|
|
"[MMM-IntelliCenter] registering for chlorinator updates...",
|
|
);
|
|
// can also check PRIM, SEC, and SUPER
|
|
// PRIM: percentage output going to primary body (probably pool) on 1-100 scale
|
|
// SEC: percentage output going to secondary body (probably spa) on 1-100 scale
|
|
// SUPER: "ON" or "OFF" for whether currently in superchlorination mode or not
|
|
await foundUnit.send(
|
|
messages.SubscribeToUpdates(chlorinatorObjnam, "SALT"),
|
|
);
|
|
}
|
|
|
|
if (intellichemObjnam) {
|
|
Log.info("[MMM-IntelliCenter] registering for chemical updates...");
|
|
await foundUnit.send(
|
|
messages.SubscribeToUpdates(intellichemObjnam, [
|
|
"PHVAL",
|
|
"PHTNK",
|
|
"ORPVAL",
|
|
"QUALTY",
|
|
]),
|
|
);
|
|
}
|
|
|
|
Log.info("[MMM-IntelliCenter] finished initial setup.");
|
|
initialConnectDone = true;
|
|
cb(poolData);
|
|
});
|
|
|
|
foundUnit.connect();
|
|
},
|
|
|
|
findServer(cb, reconnectCb) {
|
|
Log.info("[MMM-IntelliCenter] starting search for local units");
|
|
const finder = new FindUnits(this.config.multicastInterface);
|
|
finder
|
|
.on("serverFound", (server) => {
|
|
finder.close();
|
|
Log.info(
|
|
`[MMM-IntelliCenter] local unit found at ${server.addressStr}:${server.port}`,
|
|
);
|
|
|
|
foundUnit = new Unit(server.addressStr, server.port);
|
|
this.setupUnit(cb, reconnectCb);
|
|
|
|
clearInterval(unitFinderRetry);
|
|
unitFinderRetry = null;
|
|
})
|
|
.on("error", (e) => {
|
|
Log.error(
|
|
`[MMM-IntelliCenter] error trying to find a server. scheduling a retry in ${reconnectDelayMs / 1000} seconds`,
|
|
);
|
|
Log.error(e);
|
|
this.resetFoundUnit();
|
|
setTimeout(() => {
|
|
this.findServer(cb);
|
|
}, reconnectDelayMs);
|
|
});
|
|
|
|
finder.search();
|
|
unitFinderRetry = setInterval(() => {
|
|
Log.info(
|
|
`[MMM-IntelliCenter] didn't find any units within ${unitFinderTimeoutMs / 1000} seconds, trying again...`,
|
|
);
|
|
finder.search();
|
|
}, unitFinderTimeoutMs);
|
|
},
|
|
|
|
connect(cb, reconnectCb) {
|
|
if (
|
|
!foundUnit &&
|
|
typeof config !== "undefined" &&
|
|
this.config.serverAddress &&
|
|
this.config.serverPort
|
|
) {
|
|
Log.info(
|
|
`[MMM-IntelliCenter] connecting directly to configured unit at ${this.config.serverAddress}:${this.config.serverPort}`,
|
|
);
|
|
foundUnit = new Unit(this.config.serverAddress, this.config.serverPort);
|
|
}
|
|
|
|
if (foundUnit) {
|
|
this.setupUnit(cb, reconnectCb);
|
|
} else {
|
|
this.findServer(cb, reconnectCb);
|
|
}
|
|
},
|
|
});
|