Fix SLGetScheduleData documentation
This commit is contained in:
19
README.md
19
README.md
@ -658,7 +658,24 @@ Passed as an argument to the emitted `getScheduleData` event. Retrieves a list o
|
||||
|
||||
#### Properties
|
||||
|
||||
* `scheduleType` - 0 indicates regular scheduled events, 1 indicates a run-once event
|
||||
* `eventCount` - the number of `events` returned
|
||||
* `events` - array containing:
|
||||
* `scheduleId` - the associated scheduleId
|
||||
* `circuitId` - the circuit this schedule affects
|
||||
* `startTime` - the start time of the event, specified as a string in 24-hour time, so, for example, 6:00AM would be '0600' (see [conversion functions](#decodetimetime))
|
||||
* `stopTime` - the stop time of the event, specified as a string in 24-hour time, so, for example, 6:00AM would be '0600' (see [conversion functions](#decodetimetime))
|
||||
* `dayMask` - 7-bit mask that determines which days the schedule is active for, MSB is always 0, valid numbers 1-127 (see [conversion functions](#decodedaymaskmask))
|
||||
* `flags`
|
||||
* bit 0 is the schedule type, if 0 then regular event, if 1 its a run-once
|
||||
* bit 1 indicates whether heat setPoint should be changed
|
||||
* `heatCmd` - integer indicating the desired heater mode. Valid values are:
|
||||
* ScreenLogic.HEAT_MODE_OFF
|
||||
* ScreenLogic.HEAT_MODE_SOLAR
|
||||
* ScreenLogic.HEAT_MODE_SOLARPREFERRED
|
||||
* ScreenLogic.HEAT_MODE_HEATPUMP
|
||||
* ScreenLogic.HEAT_MODE_DONTCHANGE
|
||||
* `heatSetPoint` - the temperature set point if heat is to be changed (ignored if bit 1 of flags is 0)
|
||||
* `days` - which days this schedule is active for; this is just the `dayMask` property run through [`decodeDayMask()`](#decodedaymaskmask) for convenience
|
||||
|
||||
### SLSetScheduleEventById
|
||||
|
||||
|
Reference in New Issue