Updated formatting/semantics, added missing event/method documentation
This commit is contained in:
107
README.md
107
README.md
@ -213,6 +213,35 @@ Note that better/more complete handling of lighting is desired, but I have yet t
|
|||||||
|
|
||||||
Sets the salt cell's output levels. See [`SLSetSaltCellConfigMessage`](#slsetsaltcellconfigmessage) documentation for argument values. Emits the `setSaltCellConfig` event when response is acknowledged.
|
Sets the salt cell's output levels. See [`SLSetSaltCellConfigMessage`](#slsetsaltcellconfigmessage) documentation for argument values. Emits the `setSaltCellConfig` event when response is acknowledged.
|
||||||
|
|
||||||
|
### getScheduleData(scheduleType)
|
||||||
|
|
||||||
|
Retrieves a list of schedule events of the specified type. See [`SLGetScheduleData`](#slgetscheduledata) documentation for argument values. Emits the `getScheduleData` event when response is acknowledged.
|
||||||
|
|
||||||
|
### addNewScheduleEvent(scheduleType)
|
||||||
|
|
||||||
|
Adds a new event to the specified schedule type. See [`SLAddNewScheduleEvent`](#sladdnewscheduleevent) documentation for argument values. Emits the `addNewScheduleEvent` event when response is acknowledged.
|
||||||
|
|
||||||
|
### deleteScheduleEventById(scheduleId)
|
||||||
|
|
||||||
|
Deletes a scheduled event with specified id. See [`SLDeleteScheduleEventById`](#sldeletescheduleeventbyid) documentation for argument values. Emits the `deleteScheduleById` event when response is acknowledged.
|
||||||
|
|
||||||
|
### setScheduleEventById(scheduleId, circuitId, startTime, stopTime, dayMask, flags, heatCmd, heatSetPoint)
|
||||||
|
|
||||||
|
Configures a schedule event. See [`SLSetScheduleEventById`](#slsetscheduleeventbyid) documentation for argument values. Emits the `setScheduleEventById` event when response is acknowledged.
|
||||||
|
|
||||||
|
### setCircuitRuntimebyId(circuitId, runTime)
|
||||||
|
|
||||||
|
Configures default run-time of a circuit, usually referred to as the 'egg timer'. This also applies to 'run-once' programs as this will set the length of the program. See [`SLSetCircuitRuntimeById`](#slsetcircuitruntimebyid) documentation for argument values. Emits the `setCircuitRuntimeById` event when response is acknowledged.
|
||||||
|
|
||||||
|
### getPumpStatus(pumpId)
|
||||||
|
|
||||||
|
Gets information about the specified pump. See [`SLGetPumpStatus`](#slgetpumpstatus) documentation for argument values. Emits the `getPumpStatus` event when response is acknowledged.
|
||||||
|
|
||||||
|
### setPumpFlow(pumpId, circuitId, setPoint, isRPMs)
|
||||||
|
|
||||||
|
Sets flow setting for a pump/circuit combination. See [`SLSetPumpFlow`](#slsetpumpflow) documentation for argument values. Emits the `setPumpFlow` event when response is acknowledged.
|
||||||
|
|
||||||
|
|
||||||
### Events
|
### Events
|
||||||
|
|
||||||
* `loggedIn` - Indicates that a connection to the server has been established and the login process completed. `get` methods can be called once this event has been emitted.
|
* `loggedIn` - Indicates that a connection to the server has been established and the login process completed. `get` methods can be called once this event has been emitted.
|
||||||
@ -226,14 +255,17 @@ Sets the salt cell's output levels. See [`SLSetSaltCellConfigMessage`](#slsetsal
|
|||||||
* `heatModeChanged` - Indicates that a response to `setHeatMode()` has been received. Event handler receives a [`SLSetHeatModeMessage`](#slsetheatmodemessage) object.
|
* `heatModeChanged` - Indicates that a response to `setHeatMode()` has been received. Event handler receives a [`SLSetHeatModeMessage`](#slsetheatmodemessage) object.
|
||||||
* `sentLightCommand` - Indicates that a response to `sendLightCommand()` has been received. Event handler receives a [`SLLightControlMessage`](#sllightcontrolmessage) object.
|
* `sentLightCommand` - Indicates that a response to `sendLightCommand()` has been received. Event handler receives a [`SLLightControlMessage`](#sllightcontrolmessage) object.
|
||||||
* `setSaltCellConfig` - Indicates that a response to `setSaltCellOutput()` has been received. Event handler receives a [`SLSetSaltCellConfigMessage`](#slsetsaltcellconfigmessage) object.
|
* `setSaltCellConfig` - Indicates that a response to `setSaltCellOutput()` has been received. Event handler receives a [`SLSetSaltCellConfigMessage`](#slsetsaltcellconfigmessage) object.
|
||||||
|
* `getScheduleData` - Indicates that a response to `getScheduleData()` has been received. Event handler receives a [`SLGetScheduleData`](#slgetscheduledata) object.
|
||||||
|
* `addNewScheduleEvent` - Indicates that a response to `addNewScheduleEvent()` has been received which contains the created `scheduleId` to be used later for setting up the properties. Event handler receives a [`SLAddNewScheduleEvent`](#sladdnewscheduleevent) object.
|
||||||
|
* `deleteScheduleById` - Indicates that a response to `deleteScheduleById()` has been received. Event handler receives a [`SLDeleteScheduleEventById`](#sldeletescheduleeventbyid) object.
|
||||||
|
* `setScheduleEventById` - Indicates that a response to `setScheduleEventById()` has been received. Event handler receives a [`SLSetScheduleEventById`](#slsetscheduleeventbyid) object.
|
||||||
|
* `setCircuitRuntimeById` - Indicates that a response to `setCircuitRuntimeById()` has been received. Event handler receives a [`SLSetCircuitRuntimeById`](#slsetcircuitruntimebyid) object.
|
||||||
|
* `getPumpStatus` - Indicates that a response to `getPumpStatus()` has been received. Event handler receives a [`SLGetPumpStatus`](#slgetpumpstatus) object.
|
||||||
|
* `setPumpFlow` - Indicates that a response to `setPumpFlow()` has been received. Event handler receives a [`SLSetPumpFlow`](#slsetpumpflow) object.
|
||||||
* `loginFailed` - Indicates that a remote login attempt via supplying a system address and password to `UnitConnection` has failed likely due to the incorrect password being used.
|
* `loginFailed` - Indicates that a remote login attempt via supplying a system address and password to `UnitConnection` has failed likely due to the incorrect password being used.
|
||||||
* `badParameter` - Indicates that a bad parameter has been supplied to a function. This can be triggered, for example, by sending the wrong controller ID to a `set` function.
|
* `badParameter` - Indicates that a bad parameter has been supplied to a function. This can be triggered, for example, by sending the wrong controller ID to a `set` function.
|
||||||
* `error` - Indicates that an unhandled error was caught (such as the connection timing out)
|
* `error` - Indicates that an unhandled error was caught (such as the connection timing out)
|
||||||
* `addNewScheduleEvent` - will return a [`SLAddNewScheduleEvent`](#sladdnewscheduleevent) object. which contains the created `scheduleId` to be used later for setting up the properties
|
* `unknownCommand` - Indicates that an unknown command was issued to ScreenLogic (should not be possible to trigger when using the supplied `UnitConnection` methods).
|
||||||
* `deleteScheduleById` - Indicates a response to the `deleteScheduleById()` command has been received.
|
|
||||||
* `getScheduleData` - will return a [`SLGetScheduleData`](#slgetscheduledata) object. which contains a list of events of the specified type
|
|
||||||
* `setScheduleEventById` - Indicates a response to the `setScheduleEventById()` command has been received.
|
|
||||||
* `setCircuitRuntimeById` - Indicates a response to the `setCircuitRuntimeById()` command has been received.
|
|
||||||
|
|
||||||
### Properties
|
### Properties
|
||||||
|
|
||||||
@ -377,6 +409,30 @@ Returns a bool indicating whether the system has a cooler present. (Helper metho
|
|||||||
|
|
||||||
Returns a bool indicating whether the system has an IntelliChem chemical management system present. (Helper method for interpreting the value in `equipFlags`.)
|
Returns a bool indicating whether the system has an IntelliChem chemical management system present. (Helper method for interpreting the value in `equipFlags`.)
|
||||||
|
|
||||||
|
### isEasyTouch()
|
||||||
|
|
||||||
|
Returns a bool indicating whether the system is an EasyTouch system or not. (Helper method for interpreting the value in `controllerType`.)
|
||||||
|
|
||||||
|
### isIntelliTouch()
|
||||||
|
|
||||||
|
Returns a bool indicating whether the system is an IntelliTouch system or not. (Helper method for interpreting the value in `controllerType`.)
|
||||||
|
|
||||||
|
### isEasyTouchLite()
|
||||||
|
|
||||||
|
Returns a bool indicating whether the system is an EasyTouch Lite system or not. (Helper method for interpreting the value in `controllerType` and `hwType`.)
|
||||||
|
|
||||||
|
### isDualBody()
|
||||||
|
|
||||||
|
Returns a bool indicating whether the system is dual-body or not. (Helper method for interpreting the value in `controllerType`.)
|
||||||
|
|
||||||
|
### isChem2()
|
||||||
|
|
||||||
|
Returns a bool indicating whether the system is a Chem2 system or not. (Helper method for interpreting the value in `controllerType` and `hwType`.)
|
||||||
|
|
||||||
|
### getCircuitByDeviceId(deviceId)
|
||||||
|
|
||||||
|
Returns the `bodyArray` entry for the circuit matching the given device id. This is most useful with an [`SLGetPumpStatus`](#slgetpumpstatus) message.
|
||||||
|
|
||||||
### Properties
|
### Properties
|
||||||
|
|
||||||
* `controllerId` - integer indicating the controller's ID
|
* `controllerId` - integer indicating the controller's ID
|
||||||
@ -484,15 +540,15 @@ Passed as an argument to the emitted `gatewayFound` event. Contains information
|
|||||||
|
|
||||||
## SLAddNewScheduleEvent
|
## SLAddNewScheduleEvent
|
||||||
|
|
||||||
Adds a new event to the specified schedule type, either 0 for regular events or 1 for one-time events
|
Passed as an argument to the emitted `addNewScheduleEvent` event. Adds a new event to the specified schedule type, either 0 for regular events or 1 for one-time events.
|
||||||
|
|
||||||
### Properties
|
### Properties
|
||||||
|
|
||||||
* `scheduleType` - 0 - indicates regular scheduled events, 1 - indicates a run-once event
|
* `scheduleType` - 0 indicates regular scheduled events, 1 indicates a run-once event
|
||||||
|
|
||||||
## SLDeleteScheduleEventById
|
## SLDeleteScheduleEventById
|
||||||
|
|
||||||
Deletes a scheduled event with specified id
|
Passed as an argument to the emitted `deleteScheduleEventById` event. Deletes a scheduled event with specified id.
|
||||||
|
|
||||||
### Properties
|
### Properties
|
||||||
|
|
||||||
@ -500,45 +556,44 @@ Deletes a scheduled event with specified id
|
|||||||
|
|
||||||
## SLGetScheduleData
|
## SLGetScheduleData
|
||||||
|
|
||||||
Retrieves a list of schedule events of the specified type, either 0 for regular events or 1 for one-time events
|
Passed as an argument to the emitted `getScheduleData` event. Retrieves a list of schedule events of the specified type, either 0 for regular events or 1 for one-time events.
|
||||||
|
|
||||||
### Properties
|
### Properties
|
||||||
|
|
||||||
* `scheduleType` - 0 - indicates regular scheduled events, 1 - indicates a run-once event
|
* `scheduleType` - 0 indicates regular scheduled events, 1 indicates a run-once event
|
||||||
|
|
||||||
## SLSetScheduleEventById
|
## SLSetScheduleEventById
|
||||||
|
|
||||||
Configures an event with properties as described below
|
Passed as an argument to the emitted `setScheduleEventById` event. Configures an event with properties as described below.
|
||||||
|
|
||||||
### Properties
|
### Properties
|
||||||
|
|
||||||
* `scheduleId` - id of a schedule previously created, see [`SLAddNewScheduleEvent`](#sladdnewscheduleevent)
|
* `scheduleId` - id of a schedule previously created, see [`SLAddNewScheduleEvent`](#sladdnewscheduleevent)
|
||||||
* `circuitId` - id of the circuit to which this event applies to
|
* `circuitId` - id of the circuit to which this event applies
|
||||||
* `startTime` - the start time of the event, specified as minutes since midnight
|
* `startTime` - the start time of the event, specified as minutes since midnight
|
||||||
* example: 6:00am would be 360
|
* example: 6:00am would be 360
|
||||||
* example: 6:15am would be 375
|
* example: 6:15am would be 375
|
||||||
* `stopTime` - the stop time of the event, specified as minutes since midnight, format is the same as startTime
|
* `stopTime` - the stop time of the event, specified as minutes since midnight
|
||||||
* `dayMask`
|
* `dayMask`
|
||||||
* 7-bit mask that determines which days the schedule is active for, MSB is always 0, valid numbers 1-127
|
* 7-bit mask that determines which days the schedule is active for, MSB is always 0, valid numbers 1-127
|
||||||
* `flags`
|
* `flags`
|
||||||
* bit 0 is the schedule type, if 0 then regular event, if 1 its a run-once
|
* bit 0 is the schedule type, if 0 then regular event, if 1 its a run-once
|
||||||
* bit 1 indicates whether heat setPoint should be changed
|
* bit 1 indicates whether heat setPoint should be changed
|
||||||
* only valid values i've seen are 0,1,2,3
|
|
||||||
* `heatCmd` - integer indicating the desired heater mode. Valid values are: 0: "Off", 1: "Solar", 2 : "Solar Preferred", 3 : "Heat Pump", 4: "Don't Change"
|
* `heatCmd` - integer indicating the desired heater mode. Valid values are: 0: "Off", 1: "Solar", 2 : "Solar Preferred", 3 : "Heat Pump", 4: "Don't Change"
|
||||||
* `heatSetPoint` - the temperature set point if heat is to be changed (ignored if bit 1 of flags is 0)
|
* `heatSetPoint` - the temperature set point if heat is to be changed (ignored if bit 1 of flags is 0)
|
||||||
|
|
||||||
## SLSetCircuitRuntimeById
|
## SLSetCircuitRuntimeById
|
||||||
|
|
||||||
Configures default run-time of a circuit, usually referred to as the 'egg timer', this also applies to 'run-once' programs as this will set the length of the program
|
Passed as an argument to the emitted `setCircuitRuntimebyId` event. The passed version is empty, however, since the response is just an acknowledgement of receipt of the set command. Configures default run-time of a circuit, usually referred to as the 'egg timer'. This also applies to 'run-once' programs as this will set the length of the program.
|
||||||
|
|
||||||
### Properties
|
### Properties
|
||||||
|
|
||||||
* `circuitId` - id of the circuit to which this event applies to
|
* `circuitId` - id of the circuit to which this event applies to
|
||||||
* `runTime` - integer specifying the minutes of runTime
|
* `runTime` - integer specifying the run time in minutes
|
||||||
|
|
||||||
## SLGetPumpStatus
|
## SLGetPumpStatus
|
||||||
|
|
||||||
Gets information about indicated pump
|
Passed as an argument to the emitted `getPumpStatus` event. Gets information about the specified pump.
|
||||||
|
|
||||||
### Properties
|
### Properties
|
||||||
|
|
||||||
@ -546,21 +601,23 @@ Gets information about indicated pump
|
|||||||
|
|
||||||
### Return Values
|
### Return Values
|
||||||
* `isRunning` - boolean that says if pump is running
|
* `isRunning` - boolean that says if pump is running
|
||||||
* `pumpType` - 1 for IntelliFloVF (presumably), 2 for IntelliflowVS, 3 for IntelliflowVSF
|
* `pumpType` - 0 if invalid pump id or one of the IntelliFlo constants:
|
||||||
|
* ScreenLogic.PUMP_TYPE_INTELLIFLOVF
|
||||||
|
* ScreenLogic.PUMP_TYPE_INTELLIFLOVS
|
||||||
|
* ScreenLogic.PUMP_TYPE_INTELLIFLOVSF
|
||||||
* `pumpWatts` - current Watts usage of the pump
|
* `pumpWatts` - current Watts usage of the pump
|
||||||
* `pumpRPMs` - current RPMs of the pump
|
* `pumpRPMs` - current RPMs of the pump
|
||||||
* `pumpGPMs` - current GPMs of the pump
|
* `pumpGPMs` - current GPMs of the pump
|
||||||
* `pumpSetting` - Array of 8 items each containing
|
* `pumpSetting` - Array of 8 items each containing
|
||||||
* `circuitId` - Circuit Id ( CirctuiId matched data returned by [`SLControllerConfigMessage`](#slcontrollerconfigmessage) bodyArray[i].deviceId)
|
* `circuitId` - Circuit Id (CircuitId matched data returned by [`SLControllerConfigMessage`](#slcontrollerconfigmessage)'s `getCircuitByDeviceId()`)
|
||||||
* `pumpSetPoint` = the setPoint for this pump/circuit combo
|
* `pumpSetPoint` - the set point for this pump/circuit combo (in either RPMs or GPMs depending on the value of `isRPMs`)
|
||||||
* `isRPMs` = 1 for RPMs; 0 for GPMs
|
* `isRPMs` - boolean indicating if the set point is in RPMs (false means it's in GPMs)
|
||||||
* `pumpUnknown1` - unknown data -- always 0
|
* `pumpUnknown1` - unknown data; always 0
|
||||||
* `pumpUnknown2` - unknown data -- always 255
|
* `pumpUnknown2` - unknown data; always 255
|
||||||
|
|
||||||
|
|
||||||
## SLSetPumpFlow
|
## SLSetPumpFlow
|
||||||
|
|
||||||
Sets Flow Setting for a Pump/Circuit combination
|
Passed as an argument to the emitted `setPumpFlow` event. The passed version is empty, however, since the response is just an acknowledgement of receipt of the set command. Sets flow setting for a pump/circuit combination.
|
||||||
|
|
||||||
### Properties
|
### Properties
|
||||||
|
|
||||||
|
@ -29,7 +29,7 @@ exports.SLGetPumpStatus = class SLGetPumpStatus extends SLMessage {
|
|||||||
this.pumpSetting = new Array(8);
|
this.pumpSetting = new Array(8);
|
||||||
|
|
||||||
this.pumpType = this.readUInt32LE();
|
this.pumpType = this.readUInt32LE();
|
||||||
this.isRunning = this.readUInt32LE() !== 0; // Sometimes 1, sometimes 4294967295 (FF FF FF FF)
|
this.isRunning = this.readUInt32LE() !== 0; // 0, 1, or 4294967295 (FF FF FF FF)
|
||||||
this.pumpWatts = this.readUInt32LE();
|
this.pumpWatts = this.readUInt32LE();
|
||||||
this.pumpRPMs = this.readUInt32LE();
|
this.pumpRPMs = this.readUInt32LE();
|
||||||
this.pumpUnknown1 = this.readUInt32LE(); // Always 0
|
this.pumpUnknown1 = this.readUInt32LE(); // Always 0
|
||||||
|