* added GetPumpStatus / SetPumpFlow commands * Updated README.md with GetPumpStatus / SetPumpFlow information * rename `setPointType` to `isRPMs` * renamed val0 to pumpType and val1 to isRunning * added `unknown command` case * fixed lint error * Renamed unknown values to pumpUnknown1 and pumpUnknown2 * renamed 30 to unknownCommand
51 lines
1.2 KiB
JavaScript
51 lines
1.2 KiB
JavaScript
'use strict';
|
|
|
|
const SLMessage = require('./SLMessage.js').SLMessage;
|
|
|
|
const MSG_ID = 12584;
|
|
|
|
exports.SLGetPumpStatus = class SLGetPumpStatus extends SLMessage {
|
|
constructor(buf, pumpId) {
|
|
var size;
|
|
if (buf) {
|
|
size = buf.readInt32LE(4) + 8;
|
|
}
|
|
super(0, MSG_ID, size);
|
|
|
|
if (!buf) {
|
|
this.writeInt32LE(0);
|
|
this.writeInt32LE(pumpId);
|
|
} else {
|
|
this._wroteSize = true;
|
|
this.writeBuffer(buf, 0);
|
|
|
|
this.decode();
|
|
}
|
|
}
|
|
|
|
decode() {
|
|
super.decode();
|
|
|
|
this.pumpSetting = new Array(8);
|
|
|
|
this.pumpType = this.readUInt32LE();
|
|
this.isRunning = this.readUInt32LE() !== 0; // Sometimes 1, sometimes 4294967295 (FF FF FF FF)
|
|
this.pumpWatts = this.readUInt32LE();
|
|
this.pumpRPMs = this.readUInt32LE();
|
|
this.pumpUnknown1 = this.readUInt32LE(); // Always 0
|
|
this.pumpGPMs = this.readUInt32LE();
|
|
this.pumpUnknown2 = this.readUInt32LE(); // Always 255
|
|
|
|
for (var i = 0; i < 8; i++) {
|
|
this.pumpSetting[i] = {};
|
|
this.pumpSetting[i].circuitId = this.readUInt32LE();
|
|
this.pumpSetting[i].pumpSetPoint = this.readUInt32LE();
|
|
this.pumpSetting[i].isRPMs = this.readUInt32LE(); // 1 for RPMs; 0 for GPMs
|
|
}
|
|
}
|
|
|
|
static getResponseId() {
|
|
return MSG_ID + 1;
|
|
}
|
|
};
|