@ -136,7 +136,7 @@ Requests controller configuration from the connected unit. Emits the `controller
### Events
* `loggedIn`
* `loggedIn` - Indicates that a connection to the server has been established and the login process completed. `get` methods can be called once this event has been emitted.
* `version` - Indicates that a response to `getVersion()` has been received. Event handler receives a [`SLVersionMessage`](#slversionmessage) object.
* `poolStatus` - Indicates that a response to `getPoolStatus()` has been received. Event handler receives a [`SLPoolStatusMessage`](#slpoolstatusmessage) object.
* `chemicalData` - Indicates that a response to `getChemicalData()` has been received. Event handler receives a [`SLChemDataMessage`](#slchemdatamessage) object.
@ -193,11 +193,11 @@ Returns a bool indicating whether the pool is currently active or not.
* `spaDelay` - byte
* `cleanerDelay` - byte
* `airTemp` - integer representing the current temperature (check controller config to see if it's in celsius or fahrenheit)
* `currentTemp` - array of size 0-2 indicating current temperature of each body as an integer (spa/pool) (check controller config to see if it's in celsius or fahrenheit)
* `heatStatus` - array of size 0-2 indicating whether heat is active or not for each body as an integer (spa/pool)
* `setPoint` - array of size 0-2 holding the heating set point for each body as an integer (spa/pool) (check controller config to see if it's in celsius or fahrenheit)
* `coolSetPoint` - array of size 0-2 holding the cooling set point for each body as an integer (spa/pool) (check controller config to see if it's in celsius or fahrenheit)
* `heatMode` - array of size 0-2 indicating whether heating is enabled or not for each body as an integer (spa/pool)
* `currentTemp` - array of size 0-2 indicating current temperature of each body as an integer (pool: 0, spa: 1) (check controller config to see if it's in celsius or fahrenheit)
* `heatStatus` - array of size 0-2 indicating whether heat is active or not for each body as an integer (pool: 0, spa: 1)
* `setPoint` - array of size 0-2 holding the heating set point for each body as an integer (pool: 0, spa: 1) (check controller config to see if it's in celsius or fahrenheit)
* `coolSetPoint` - array of size 0-2 holding the cooling set point for each body as an integer (pool: 0, spa: 1) (check controller config to see if it's in celsius or fahrenheit)
* `heatMode` - array of size 0-2 indicating whether heating is enabled or not for each body as an integer (pool: 0, spa: 1)
* `circuitArray` - array holding all circuits in the system
* `id` - integer representing the circuit's ID (spa is 500, pool is 505)
* `state` - integer indicating whether the circuit is on or not (0/1)
@ -257,8 +257,8 @@ Passed as an argument to the emitted `controllerConfig` event handler.
### Properties
* `controllerId` - integer indicating the controller's ID
* `minSetPoint` - array (size 2) indicating the minimum setpoint available for the pool or spa
* `maxSetPoint` - array (size 2) indicating the maximum setpoint available for the pool or spa
* `minSetPoint` - array (size 2) indicating the minimum setpoint available for the pool (index 0) or spa (index 1)
* `maxSetPoint` - array (size 2) indicating the maximum setpoint available for the pool (index 0) or spa (index 1)
* `degC` - boolean indicating whether the system is using the centigrade scale for temperatures or not
* `controllerType` - byte
* `hwType` - byte