Commit Graph

32 Commits

Author SHA1 Message Date
ee30cd815e GetPumpStatus isRPMs changed to bool to be consistent with SetPumpStatus 2020-06-09 08:42:26 -05:00
bf3902efe8 Updated formatting/semantics, added missing event/method documentation 2020-06-09 08:41:15 -05:00
e6acd36562 Added helper to get the number of pumps installed in a system 2020-06-09 08:39:38 -05:00
75d642cbfc GetPumpStatus / SetPumpFlow commands (#28)
* added GetPumpStatus / SetPumpFlow commands

* Updated README.md with GetPumpStatus / SetPumpFlow information

* rename `setPointType` to `isRPMs`

* renamed val0 to pumpType and val1 to isRunning

* added `unknown command` case

* fixed lint error

* Renamed unknown values to pumpUnknown1 and pumpUnknown2

* renamed 30 to unknownCommand
2020-06-09 07:49:24 -05:00
cd981c19ef Added ability to get circuit info by the device id
This is useful for EquipmentConfiguration and upcoming PumpStatus messages.
2020-06-08 22:14:31 -05:00
8d908aad5d WIP interpretation of equipment configuration properties 2020-06-08 19:05:45 -05:00
c1ceacbd98 Updated Readme / Added EggTimer Support (#25)
* added setCircuitRuntimeById function
2020-06-06 18:57:58 -05:00
9c72e7b61d Schedule Editing Additions (#24)
* Added support for: adding schedule events, deleting schedule events, listing schedule events and updating scheduled events
2020-06-03 22:07:33 -05:00
43725ae083 Fixed remote login
I forgot that this message sometimes receives a string instead of a buffer.

Fixes #19
2020-03-04 21:56:06 -06:00
81b3a61c28 Added SLEquipmentConfigurationMessage
I am not documenting this in the readme just yet because I don't really know how to interpret the data provided, but it seems to be necessary if we want to be able to change pump speeds in the future or read any historical data about the equipment. I'm not sure how much I'm going to be able to figure out about these arrays since the data appears random to me at the moment, but perhaps others will be able to figure out what's in here.
2020-02-22 11:29:29 -06:00
a2d39e7463 Added some helpers to interpret the controllerType field
These aren't particularly useful, at least not to me, but I found them while perusing the official app, so I figured they couldn't hurt to have.
2020-02-22 11:27:09 -06:00
ed99d411b2 Minor optimization to set buffer size appropriately
This avoids unnecessary allocations/reallocations while decoding a message by pre-sizing the buffer to the amount we know it will require. I feel like there's probably a better way to handle this, but this works for now.
2020-02-10 21:36:13 -06:00
ba19b6802e Added support for reading arrays from screenlogic messages 2020-02-09 14:51:10 -06:00
c9afb53810 SLMessage now supports instancing from an encoded SLMessage
This allows the base class to be evaluated by unit tests in a way that mocks what the library does with actual messages received from pool equipment.
2020-02-09 14:39:43 -06:00
22357f11e2 Encapsulate alignment into a function to make things slightly easier
This just returns the extra amount needed to add onto the string/array.

Also fixed up writeSLArray() not adding slack like it should have been. This wasn't an issue previously because the only place that currently uses this function is the password feature which is a fixed 16byte length, so it was already aligned. An upcoming commit will be using this, however, so I needed the alignment to be correct.

Finally, the read/write string functions were doing unnecessary conditional checks so I removed them. skipWrite() already does nothing if you tell it to skip 0, and adding 0 to readOffset won't do anything, so neither conditional is necessary at this point.
2020-02-09 14:28:03 -06:00
22858061f7 eslint didn't like these not having semi-colons
I should probably turn the semi-colon linter off since I really dislike the semi-colons everywhere, but it's probably too late for that at this point in the project.
2020-02-09 14:22:32 -06:00
0397e8ad8f Added support for controlling the salt cell generator output levels
Closes #17
2020-02-08 15:33:13 -06:00
661d8db173 Added helper methods for interpreting the equipFlags value
Provided by @mikemucc in #15. Also updated the readme with the new information.
2019-12-27 15:57:21 -06:00
757a3be7d1 Set heat mode (#13)
* Function to set the heater mode + readme updates

* making the test set the heater to 'heat pump'
2019-11-24 16:53:53 -06:00
5ec3fbb802 Added ability to send light commands (on, off, set colors, etc.)
This implementation is barebones and only does what I was able to find easily in the official app's source code. I'd love to do more with this, so any pull requests adding functionality would be welcomed.

Closes https://github.com/parnic/node-screenlogic/issues/4
2019-07-29 21:37:36 -05:00
cf3d3cba78 Fixed eslint complaint from commit 3824437 2019-06-21 00:13:11 -05:00
1aa1dddb49 Added ability to set pool or spa heat setpoint
Fixes #9
2019-06-21 00:12:29 -05:00
3824437d7a Factor out circuitData() and use it for is{Spa,Pool}Active (#8) 2019-06-14 16:53:42 -05:00
a09df2569b Added support for remote + passworded access
This password encoder was decompiled from the Android app then manually cleaned up and ported to Javascript. It ain't pretty, but it works.

I don't know that this is all necessarily the most correct or idiomatic way to implement these features, but I wanted to make sure the functionality got committed to help out people wanting to use this for smart home appliances (#1).
2019-02-22 16:06:11 -06:00
3c6b8ebcc7 Linter fixes 2018-04-28 23:06:11 -05:00
e1c775b8a8 Added ability to set circuit state
This allows for, for example, turning on a water feature or changing pool/spa active status.
2018-04-16 19:49:01 -05:00
a383f8ca97 Ensure isValid is always set 2018-03-31 08:42:16 -05:00
0bbae0446b Removed debug logging
Added verification of broadcast response message size
Added clearer handling of message types

I'm sure there's a better way to do debug logging, but I don't really feel like adding a dependency on another module just for that.
2018-03-30 20:35:24 -05:00
ce41d6b009 Added quick way to check if pool/spa are on
Added interpreters for 'ok' variable
2018-03-30 20:15:42 -05:00
8c02b4857d degC is now true/false instead of 0/1
Seek ahead instead of using padding variables
2018-03-30 20:14:08 -05:00
3262ac428b Added chem data
Added salt cell config
Added system version
Tweaked pool status to pre-adjust values

Chem data uses big endian encoding for most of its values (but not all) while everything else (so far) has used little endian. Chem data also encodes bits like whether there's a system error or not inside other pieces of data like salt levels. There are also bytes in the returned data that I don't know the significance of just yet.
Pool status was tweaked such that asking for pH is corrected down to its proper float representation (e.g. 7.60) instead of the integer representation that is sent by the system (760). Same for water balance/saturation. Salt now returns the proper value (scaled up by 50) instead of the value sent over by the system, which I guess is the maximum precision the system can provide.
2018-03-30 19:59:17 -05:00
b6ee816fb3 Added decoding of messages
Also moved things out to their own files and setup require()s to bring it all together.
2018-03-30 16:07:56 -05:00